Independent Australian Storage & Infrastructure Authority

Unraid Parity Rebuild + Parity Check Estimator

This estimator works out how long an Unraid data-disk rebuild or parity build takes, how long the array runs with reduced protection once you add the wait for a replacement, what protection is left while it runs, and what to check before you start. For a routine parity check it shows the same estimate as our parity check calculator.

When a disk drops out of an Unraid array, parity is what lets its contents be rebuilt. Until the rebuild finishes, single parity has no redundancy left and dual parity has one disk to spare. The length of that window, and what you check before starting, are the parts you control.

Operation
Speed
The average speed of a past rebuild or parity check on this server. It replaces the assumed speed and the activity setting.
During a disk rebuild Maintenance Mode can optionally be selected to speed up the rebuild; the array is not accessible while it runs. (Unraid source, applies to Current docs (no version stated), checked 2026-10-06) This tool treats it as an array with nothing else running and applies no fixed speed-up.
Replacement and risk
Do not treat this as an ordinary rebuild. Investigate first.

A rebuild or parity build reads every disk hard for hours. With another disk already showing problems, that is when it is most likely to fail too.

  • Read the warning disk's SMART report and the system log; check its cable, power and controller port.
  • If critical data is not backed up and the array is readable, consider copying the most important files first, knowing that heavy reading also stresses a weak disk.
  • If more than one disk is in trouble, get recovery advice before starting. Our guide to NAS data recovery costs in Australia covers your options.
Estimated rebuild time
…
Protection while it runs

Degraded-window risk, from independent disk failures

Before you start
  • A disabled disk is not always a dead one. A failed/disabled disk (red X) is not always broken (bad connection, power issue, glitch); a disabled disk judged healthy can be rebuilt onto itself instead of replaced. (Unraid source, applies to Current docs (no version stated), checked 2026-10-06) Check its SMART report, cable and power before you buy a replacement.
  • Check the emulated disk. While a disk is disabled, Unraid emulates it from parity plus the other working drives, and its data stays accessible. (Unraid source, applies to Current docs (no version stated), checked 2026-10-06) Before rebuilding, confirm it mounts and its files look right: a rebuild reproduces what parity holds, it does not repair a damaged filesystem.
  • Check every other disk. Look at SMART on each, especially pending and reallocated sectors, and reseat cables.
  • Backups. A backup reduces what you lose if this goes wrong; it does not make the rebuild safer. If your critical data is not backed up, consider copying it first.
  • Replacement size. Each parity disk must be at least as large as the largest data disk (dual parity: both, but they may differ in size from each other). (Unraid source, applies to Current docs (no version stated), checked 2026-10-06) If your replacement is larger than the parity disk: A parity swap procedure exists for replacing a data disk with one larger than the current parity disk. (Unraid source, applies to Current docs (no version stated), checked 2026-10-06) That is a multi-stage job, not one rebuild, and this tool does not time it.
Routine parity check at the same speed

Plan it in the Parity Check Calculator →

How we calculate

Assumed average speeds (MB/s)
Slowest disksRebuild or parity buildParity check (reads)
7200 rpm class hard drives120 to 160120 to 160
5400 rpm class or older hard drives90 to 12090 to 120
An SMR hard drive in the array40 to 11090 to 120
SATA SSDs150 to 300400 to 550
Assumed effect of other activity (share of the idle speed left)
ActivitySpeed left
Idle: nothing else running100% to 100%
Light: some streaming or reads85% to 95%
Moderate: active use, some writes65% to 85%
Heavy: big copies, VMs or containers busy40% to 70%

Worked example

Four disks (three data, one parity), single parity, rebuilding an 8 TB data disk, 7200 rpm class drives, nothing else running, a spare on the shelf (about 12 hours to swap), drives at 0.87% AFR.

Rebuild, parity build and parity check compared

OperationReadsWritesProtection while it runs
Data disk rebuildParity and every other data diskThe replacement data diskSingle parity: none left. Dual parity: one more disk can fail.
Parity build (replace or upgrade)Every data diskThe parity diskOnly parity disk: none until it finishes. One of two: the other still protects.
Adding a second parity diskEvery data diskThe new parity diskThe first parity disk keeps protecting the array.
Parity checkEvery data and parity diskParity, only where a correcting check finds a mismatchFull protection; it checks it.

A parity check is timed in the Parity Check Calculator, which shares this page's speed assumptions and formula.

Unraid facts this page uses

Each fact below is taken from Unraid's own documentation or release notes, re-found at the source on the date shown. Latest stable Unraid release when checked: 7.3.3.

FactApplies toSource
What Unraid does by default
Latest stable Unraid OS release is 7.3.3 (docs release notes: 7.3.3 dated 2026-10-08).Unraid OS stable, as of 2026-10-12 (7.4.0-rc.1 dated 2026-10-08 is a pre-release)Unraid source, checked 2026-10-12
After an unsafe shutdown Unraid automatically starts a parity check using the mode set under Settings > Scheduler > Parity Check (non-correcting by default); it is not automatically a correcting check.Current docs (no version stated)Unraid source, checked 2026-10-06
What the Unraid documentation advises
During a disk rebuild Maintenance Mode can optionally be selected to speed up the rebuild; the array is not accessible while it runs.Current docs (no version stated)Unraid source, checked 2026-10-06
For array devices with sustained writes, particularly parity, the docs prefer CMR over drive-managed SMR; SMR can have significantly lower sustained write performance during parity syncs and rebuilds.Current docs (no version stated)Unraid source, checked 2026-10-06
How the array behaves
A failed/disabled disk (red X) is not always broken (bad connection, power issue, glitch); a disabled disk judged healthy can be rebuilt onto itself instead of replaced.Current docs (no version stated)Unraid source, checked 2026-10-06
While a disk is disabled, Unraid emulates it from parity plus the other working drives, and its data stays accessible.Current docs (no version stated)Unraid source, checked 2026-10-06
Each parity disk must be at least as large as the largest data disk (dual parity: both, but they may differ in size from each other).Current docs (no version stated)Unraid source, checked 2026-10-06
A parity swap procedure exists for replacing a data disk with one larger than the current parity disk.Current docs (no version stated)Unraid source, checked 2026-10-06
Adding a parity disk works like adding a data disk: assign it and start the array; parity builds while files stay accessible, possibly slower. Either parity disk must be at least the largest data disk.Current docs (no version stated)Unraid source, checked 2026-10-06
Unraid does not stripe across drives: each file is stored on a single disk.Current docs (no version stated)Unraid source, checked 2026-10-06
Unraid's parity-protected array holds up to 30 devices, 28 data and 2 parity, on an Unleashed or Lifetime licence; a Starter licence allows up to 6 devices including parity.Current licence tiers (licensing FAQ, current docs)Unraid source, checked 2026-10-14

Spares, warranty and recovery

The wait for a replacement counts as degraded time, and it is often longer than the rebuild. A spare on the shelf removes most of it; a warranty claim usually adds to it, because the replacement comes back after the failed drive goes in. Enter the wait you would really have above. A manufacturer warranty is the maker's own promise. Your first step for a faulty product is usually the retailer that sold it. The ACCC explains your rights under the Australian Consumer Law at accc.gov.au.

If a rebuild fails, restore from backup. Without one, professional recovery is possible in many cases; providers include Payam Data Recovery and Ontrack, and quotes vary by failure type. See NAS data recovery costs in Australia.

Frequently Asked Questions

How long does an Unraid disk rebuild take?
About the size of the disk being rebuilt divided by the speed the rebuild progresses at. At 120 to 160 MB/s an 8 TB disk takes about 14 h to 19 h. The slowest disk, the controller and other activity set the pace, so the best figure is the average speed of a past parity check or rebuild on your own server. Enter it as your observed speed.
Is a disabled disk a failed drive?
A failed/disabled disk (red X) is not always broken (bad connection, power issue, glitch); a disabled disk judged healthy can be rebuilt onto itself instead of replaced. Check the disk's SMART report, its cable and power, and the system log before you buy a replacement.
What should I check before starting a rebuild?
While a disk is disabled, Unraid emulates it from parity plus the other working drives, and its data stays accessible. Also check SMART on every other disk, reseat cables, and make sure no second disk is showing errors.
Should I rebuild in Maintenance Mode?
During a disk rebuild Maintenance Mode can optionally be selected to speed up the rebuild; the array is not accessible while it runs. This tool does not apply a fixed speed-up for it: it treats Maintenance Mode as an array with nothing else running.
What happens if another disk fails during the rebuild?
With single parity, one more disk failing before the rebuild finishes is more than parity can rebuild, and data can be lost. With dual parity, the array can lose one more disk and still rebuild. Unraid does not stripe across drives: each file is stored on a single disk. A backup is what covers a loss beyond parity.
Will one unreadable sector ruin the rebuild?
An unreadable sector on another disk is not the same as a second disk failing. NTK's reading: with no redundancy left it affects the data in that place, typically part of one file, not the whole rebuild. With dual parity there is still parity to rebuild that block. Regular parity checks find weak sectors while redundancy is still intact.
Can I rebuild onto an SMR drive?
For array devices with sustained writes, particularly parity, the docs prefer CMR over drive-managed SMR; SMR can have significantly lower sustained write performance during parity syncs and rebuilds. SMR drives can slow down badly under long sustained writes, which a rebuild is, by an amount that varies by model and how full the drive cache is. This tool uses a deliberately wide range for an SMR target instead of a fixed penalty, and a speed you have observed on your own server beats it.
Should I back up before a rebuild?
A backup reduces what you lose if the rebuild goes wrong; it does not make the rebuild itself safer. If your critical data is not backed up and the array is readable, consider copying the most important files first. If more than one disk is showing problems, get recovery advice before you start, because heavy reading can push a failing disk over.

Method last reviewed: 2026-10-14. Unraid facts last checked at source: 2026-10-14.