This RAID usable capacity calculator shows how much space you get for your files from Synology SHR, SHR-2, RAID 0, 1, 5, 6 and 10, an Unraid array or a ZFS vdev, with mixed drive sizes. Each layer is a separate line: redundancy, space mixed drives leave unused, what the NAS platform reserves, and the free space you choose to keep.
Results are in decimal TB, the unit drives are sold in. Synology and QNAP reserves are quoted from their own documentation, with the source and date under How we calculate. The expansion planner shows when replacing or adding drives actually adds space.
How SHR uses each size tier
Pick a change for the array above. The planner applies it one drive at a time, the way the platform does it, and shows the capacity after each step. Space often does not appear after the first bigger drive.
Rebuild time here is the new drive's full capacity at the speed range you picked, an NTK planning assumption. For Synology Fast Repair, a custom speed and the risk while the array is degraded, use the RAID Rebuild Time and Risk Estimator.
Conventional RAID accepts drives of different sizes. Classic RAID on Synology sizes every member to the smallest drive in the pool; space above it is unused. (Synology, checked 2026-10-07)
Synology states pool capacity as: RAID 5 = (drives minus 1) x smallest drive; RAID 6 = (drives minus 2) x smallest; RAID 10 = (drives / 2) x smallest. (Synology, checked 2026-10-07)
Synology Hybrid RAID (SHR) splits the drives into size tiers and protects each tier on its own, so larger drives add space when enough of them reach a tier. That makes it more capacity-efficient than conventional RAID with mixed sizes, but not every combination uses every terabyte: the calculator shows what is left unused. Synology's own RAID Calculator counts SHR-2 capacity only where at least four drives reach a size tier; capacity above the fourth largest drive is counted as unused. (Synology RAID Calculator, checked 2026-10-07)
| Drives | SHR-1 | RAID 5 | SHR-2 | RAID 6 |
|---|---|---|---|---|
| 4 x 4 TB | 12 TB | 12 TB | 8 TB | 8 TB |
| 2 + 4 + 4 + 8 TB | 10 TB (4 TB unused) | 6 TB (10 TB unused) | 4 TB (10 TB unused) | 4 TB (10 TB unused) |
| 4 + 4 + 8 + 8 TB | 16 TB | 12 TB | 8 TB | 8 TB |
Layout capacity before platform reserves, decimal TB. SHR-1 and RAID 5 survive one failed drive; SHR-2 and RAID 6 survive two.
| Layout | After 1st | After 2nd | After 3rd | After 4th |
|---|---|---|---|---|
| Synology SHR-1 | 12 TB | 16 TB | 20 TB | 24 TB |
| Synology SHR-2 | 8 TB | 8 TB | 8 TB | 16 TB |
| Synology RAID 5 | 12 TB | 12 TB | 12 TB | 24 TB |
| QNAP RAID 5 | 12 TB | 12 TB | 12 TB | 24 TB |
There is no drive size where single parity stops being reasonable. What matters is how long your array would run degraded and what a loss would cost you. These push towards dual parity (SHR-2, RAID 6, RAIDZ2):
The cost is one more drive of capacity, which this calculator shows. To put numbers on the window for your own array, use the RAID Rebuild Time and Risk Estimator and the Drive Failure Risk Estimator.
| Fact | Source | Checked |
|---|---|---|
| Conventional RAID and SHR (Synology) | ||
| Classic RAID on Synology sizes every member to the smallest drive in the pool; space above it is unused. | Synology Knowledge Center | 2026-10-07 |
| Synology states pool capacity as: RAID 5 = (drives minus 1) x smallest drive; RAID 6 = (drives minus 2) x smallest; RAID 10 = (drives / 2) x smallest. | Synology Knowledge Center | 2026-10-07 |
| Synology's own RAID Calculator counts SHR-2 capacity only where at least four drives reach a size tier; capacity above the fourth largest drive is counted as unused. | Synology Knowledge Center | 2026-10-07 |
| Synology's RAID Calculator counts RAID 0 as the sum of every drive, not drives x smallest drive. | Synology Knowledge Center | 2026-10-07 |
| Synology reserves | ||
| Synology's RAID Calculator reserves about 10 GB per drive for the DSM system and swap partitions. | Synology Knowledge Center | 2026-10-07 |
| When a volume is created, Synology reserves 4% of its capacity for Btrfs metadata, or 2% for ext4. | Synology Knowledge Center | 2026-10-07 |
| Synology expansion | ||
| On an SHR pool of equal sized drives, capacity grows only after at least two drives (SHR-1) or four drives (SHR-2) have been replaced with larger ones, one at a time. | Synology Knowledge Center | 2026-10-07 |
| On an SHR pool of mixed sizes, Synology says to replace the smallest drives with drives at least as large as the largest drive already in the pool. | Synology Knowledge Center | 2026-10-07 |
| On classic RAID (not SHR) with equal sized drives, every drive must be replaced with a larger one before capacity grows. | Synology Knowledge Center | 2026-10-07 |
| On classic RAID with mixed sizes, replacing a drive other than the smallest does not change capacity; the smallest must be replaced first. | Synology Knowledge Center | 2026-10-07 |
| Synology Storage Manager replaces one drive at a time. | Synology Knowledge Center | 2026-10-07 |
| Synology allows expansion by adding drives on JBOD, RAID 5, RAID 6, RAID TP, RAID F1, SHR-1 and SHR-2 (not RAID 0, RAID 1 or RAID 10). | Synology Knowledge Center | 2026-10-07 |
| A drive added to a Synology RAID 1, 5, 6 or F1 pool must be at least as large as the smallest drive in the pool. | Synology Knowledge Center | 2026-10-14 |
| A drive added to a Synology SHR pool must be at least as large as the smallest drive in the pool. | Synology Knowledge Center | 2026-10-14 |
| Adding a second drive to a single drive SHR pool adds redundancy only; capacity grows from the third drive. | Synology Knowledge Center | 2026-10-07 |
| Adding drives to a Synology RAID 1 pool adds mirror copies, not capacity (Synology RAID 1 is an N-way mirror). | Synology Knowledge Center | 2026-10-07 |
| Synology's Replace Drive option needs a storage pool of at least two drives. On one-bay models without it, Synology says to back up your data to another place before replacing the drive. | Synology Knowledge Center | 2026-10-14 |
| QNAP reserves and expansion | ||
| QNAP reserves about 70 GB per storage pool and 20 GB per static volume for storage configuration data. | QNAP | 2026-10-07 |
| QNAP also reserves 1% of each RAID group's total capacity for RAID metadata, up to 150 GB per group. | QNAP | 2026-10-07 |
| On QNAP ext4 volumes over 100 GB, file system metadata takes between 0.8% and 1.8% of the volume (larger volumes need less). | QNAP | 2026-10-07 |
| QNAP pool guaranteed snapshot space is an option that reserves pool space for snapshots; when set as a percentage the default is 20% of the pool. | QNAP | 2026-10-07 |
| On QNAP the Expand Capacity step becomes available only after every disk in the RAID group has been replaced and rebuilt. | QNAP | 2026-10-07 |
| QNAP supports expanding by replacing disks on RAID 1, 5, 6 and 10; capacity then follows the smallest drive. | QNAP | 2026-10-07 |
| QNAP can add disks to RAID 1, 5, 6, 50 and 60 groups while the pool stays online; each added disk must be at least as large as the smallest in the group. | QNAP | 2026-10-07 |
| Adding disks to a QNAP RAID 1 group converts it to RAID 5. | QNAP | 2026-10-07 |
| Hot spares and platform limits | ||
| On Synology, a hot spare for an SHR storage pool must be at least as large as the largest drive in the pool. | Synology DSM 7.2 User Guide | 2026-10-11 |
| On Synology, a hot spare for a RAID 1, 5, 6, 10 or F1 storage pool must be at least as large as the smallest drive in the pool. | Synology DSM 7.2 User Guide | 2026-10-11 |
| ZFS accepts a replacement disk for a mirror or RAIDZ vdev only if it is at least as large as the smallest disk in that vdev. | OpenZFS | 2026-10-11 |
| On QNAP QTS, a RAID 1 group has exactly 2 disks, and a single RAID 0, 5, 6 or 10 group has at most 16 disks (RAID 10 an even number). | QNAP | 2026-10-11 |
| A QNAP static volume has no storage pool and does not support snapshots. | QNAP | 2026-10-11 |
| Free space | ||
| QNAP's pool and volume usage alert threshold defaults to 80% and can be changed; it is an alert, not a limit. | QNAP | 2026-10-07 |
| QNAP lists slower performance, failed snapshots or backups and refused writes as risks once a pool or volume is nearly full. | QNAP | 2026-10-07 |
| TrueNAS calls 80% full a starting point, not a hard limit: write once archival pools can reasonably run to 90 or 95%, while heavy random I/O pools may need to stay below 80%. | TrueNAS (iXsystems) | 2026-10-07 |
| ZFS | ||
| A RAIDZ group of N disks of size X with P parity disks holds approximately (N minus P) x X and survives P failed disks. | OpenZFS | 2026-10-07 |
| OpenZFS reports RAIDZ pool space as if every block were 128K, using the vdev's original width. | OpenZFS | 2026-10-14 |
| RAIDZ space efficiency depends on block size: OpenZFS's own example 3 disk RAIDZ1 stores 4K records at 50% efficiency and 128K records at about 66%; wider vdevs are more efficient. | OpenZFS | 2026-10-07 |
| OpenZFS holds back 1/32 (about 3.2%) of a pool by default (spa_slop_shift=5); with less free space than that, most writes and file creates fail with an out of space error. | OpenZFS | 2026-10-07 |
| The OpenZFS slop reserve is 1/32 of pool space, capped at 128 GiB, and never less than 128 MiB (or half the pool on a pool smaller than 256 MiB). | OpenZFS | 2026-10-14 |
| When ZFS drives are replaced with larger ones, the new space appears only after every disk in that mirror or RAIDZ group is larger (autoexpand, off by default). | OpenZFS | 2026-10-07 |
| Attaching a disk to a ZFS mirror adds another copy (two way becomes three way); it adds redundancy, not capacity. | OpenZFS | 2026-10-07 |
| RAIDZ expansion (adding a disk to an existing RAIDZ vdev) is a feature of OpenZFS 2.3.0. | OpenZFS | 2026-10-07 |
| RAIDZ expansion keeps the parity level (a RAIDZ2 stays a RAIDZ2), can be repeated, and the added disk must be at least as large as the smallest disk in the vdev. | OpenZFS | 2026-10-07 |
| After RAIDZ expansion, blocks written before it keep their old data to parity ratio; only new blocks use the wider ratio, and tools may report slightly less space than expected. | OpenZFS | 2026-10-07 |
| Unraid | ||
| Adding a data disk to an Unraid array expands its capacity. | Unraid documentation | 2026-10-07 |
| Replacing an Unraid data disk with a larger one rebuilds onto it and the file system grows to the new disk's size. | Unraid documentation | 2026-10-07 |
| A data disk added to an Unraid array must be no larger than the parity disks; a larger disk means upgrading parity first. | Unraid documentation | 2026-10-07 |
| Each parity disk must be at least as large as the largest data disk (dual parity: both, but they may differ in size from each other). | Unraid documentation | 2026-10-06 |
| A parity swap procedure exists for replacing a data disk with one larger than the current parity disk. | Unraid documentation | 2026-10-06 |
| Unraid does not stripe across drives: each file is stored on a single disk. | Unraid documentation | 2026-10-06 |
| Drive sizes | ||
| Seagate's IronWolf Pro NAS drive range goes up to 32 TB. | Seagate | 2026-10-07 |
| WD Red Pro NAS drives come in capacities from 2 TB to 26 TB. | Western Digital | 2026-10-07 |
Vendor figures and rules checked at source: 2026-10-06 to 2026-10-14.
Raw capacity 16 TB. SHR-1 uses one drive's worth for redundancy: layout capacity 12 TB. The system partitions take 0.04 TB and Btrfs metadata 0.48 TB, leaving 11.48 TB available. Keeping 10% free, plan on storing about 10.33 TB. In binary units the available space is about 10.44 TiB.
NAS-grade drives sold by Australian retailers, with the current market price for each. Compare individual retailers on Staticice.
| Drive | Capacity | AU market price |
|---|---|---|
| Seagate IronWolf | 4 TB | $352 |
| Seagate IronWolf | 6 TB | Check retailers |
| Seagate IronWolf | 8 TB | $635 |
| Seagate IronWolf | 12 TB | $920 |
| Seagate IronWolf | 16 TB | $1225 |
| WD Red Plus | 4 TB | $336 |
| WD Red Plus | 8 TB | $594 |
| WD Red Plus | 12 TB | $899 |
Market prices, last changed 23 October 2026. Each figure is the typical going rate across the Australian retailers we track, checked daily against their listings. A drive stocked by fewer than 3 retailers shows no price. Confirm the price with the retailer before you buy.
Warranty: a drive's warranty term is the manufacturer's own, so check its datasheet. Your first step for a faulty product is usually the retailer that sold it. The ACCC explains your rights under the Australian Consumer Law at accc.gov.au. The array runs with less redundancy until a replacement arrives and rebuilds, so a spare drive on the shelf shortens that wait.
RAID is not a backup. It keeps your files available when a drive fails. It does not undo deletion, ransomware, theft or a fire, so keep a separate backup. Read our 3-2-1 backup guide.
Planning a full NAS build? Our Verified Build Plans include a complete shopping list with a compatible NAS, drives and accessories, a drive compatibility check and an expansion roadmap.
Want a second opinion on your RAID choice? Review My Build looks at your RAID level, drive selection and backup plan.
A 1-page worksheet covering drive count, RAID type, usable capacity and rebuild planning. Fill it in before you buy drives or build a NAS.
Ask us anything about NAS, storage, or infrastructure. We reply by email.
Message sent!
We'll be in touch soon.